Chang Jae Kim 2 Articles
Intracardiac Knotting of a Balloon-tipped, Flow-directed Pulmonary Artery Catheter: A Case Report
Bong Chul Choi, Mee Young Chung, Chang Jae Kim, Jun Seuk Chea, Byung Ho Lee
Korean J Crit Care Med. 2005;20(2):178-182.
  • 1,581 View
  • 12 Download
AbstractAbstract PDF
The occurrence of knots and loops is a potential hazard of a balloon-tipped, flow-directed pulmonary artery (PA) catheter placement if excessive catheter length is passed into the right atrium or ventricle. Knotting of a balloon-tipped, flow-directed PA catheter leading to difficulty in its removal is a rare but serious complication. A case of knotted catheter in right atrium in a patient undergoing aortic valve replacement is presented. By passing a spring guidewire into PA catheter, we have untied the loose knotted catheter under simple fluoroscopic guidance in the intensive care unit.
The Comparison of Buccal SpO2 and Finger SpO2 Accuracy in Patients with Moderate Defect in Pulmonary Function Test
Mee Young Chung, Jun Seuk Chea, Chang Jae Kim, Byung Ho Lee, Seung Ho Joo
Korean J Crit Care Med. 2000;15(1):31-34.
  • 1,598 View
  • 18 Download
AbstractAbstract PDF
BACKGROUND
The reliability of pulse oxymetry probes when applied to the finger or toes may be compromised in certain patients. Other sites less subject to mechanical interference or a pathophysiologic decrease in pulse amplitude have been sought. In the patients with moderate defect (N=20) in pulmonary function test, we examined the accuracy of buccal and digital SpO2 (oxygen saturation of pulse oxymetry) monitoring.
METHODS
SpO2 probe was placed firmly in the corner of the patient's mouth. Buccal and finger SpO2 and radial SaO2 (arterial oxygen saturation) were measured before the induction of anesthesia. The agreement between SaO2 and each SpO2 were calculated with the method outlined by Bland and Altman.
RESULTS
Buccal SpO2 was higher than finger SpO2, but finger SpO2 agreed more closely with SaO2 (buccal; 97.9+/-1.89, finger; 94.5+/-2.48, radial; 93.73+/-2.73%).
CONCLUSIONS
We conclude that buccal SpO2 monitoring may offer alternative when other sites aren't available. But, we suggest that buccal SpO2 should be further evaluated for the accuracy.